Shimadzu

SKU: ShimadzuSCL10AVP

Home → Welcome to Shimadzu Scientific US Webstore COVID-19 update: Currently we are processing web store orders in accordance with our standard operating procedures. NOTE: All discounts, coupons and promotions displayed on the web store are valid for web store orders only. Part number description fob price 011-30398-11 clean tube,ba1/8x0.5 $42.93 011-30407-84 sus 304 tube od2x0.5t $15.26 011-30410 sst pipe,sus304tp 3x0.5 $23.63 011-30410-01 sst pipe,sus304tp-semi 3x0.5 $15.26 011-35332 wire,sst sus304-w1 0.50 $4.59 013-000-71 $161.33 014-54309 pt-ni band, 13mg $106.65 014-54620 pt wire,ptw 0.2 $83.03 014-54635 pt wire,ptw 0.7 $425.79 014-54710. Moreover, a SCSI connector offers access to all DIO channels. The units can be operated with standard 90 - 240 V mains supply or by an external 12 V DC power supply (e.g., an external battery pack) to break up ground loops. 202-46400-03 sample plate 6 mm $1.209,23 202-46400-04 sample plate 8 mm $1.209,23 202-46401 screw receiver $98,78 202-46405 electrode holder assy $1.491,35 202-46405-01 electrode holder assembly $1.626,03 202-46406 sample holder plate,round type $1.209,23 202-46408 gvm sample task flat $1.318,76 202-46408-01 sample holder plate,no groove $1.318,76 202-46408-02 sample plate.

Web Information

Shimadzu's SCL-10AVP System Controller directly controls all VP Series components from it's simplified display menu for easy,user-friendly operation. All Shimadzu HPLC system modules are conveniently linked to the controller by fiber optic cables for swift 'Plug-and-Play' set-up. Fiber optic interfacing enables low noise,high-speed data transmission which enhances system reliability and sensitivity. An optional SCSI interface allows multiple VP Series HPLC systems to be linked.

Shimadzu

Features:

Scsi

-The new controller features many improvements including a larger, more legible display and customizable menus which simplify system operation for novice and advanced users. Menus can now be tailored to see only the parameters that you care about. Function keys,detailed help information(with valid parameter ranges), and a graphical user interface streamline parameter setup and instrument operation.

-Built-in validation support functions help you comply with GLP/GMP regulations and enhance productivity by reducing the labor required to perform validation tasks. A record of each module's operation is preserved and can be reviewed on-screen.

-Save method parameters to the built-in 3.5' disk drive for reference and for secure transfer to other VP Series HPLC systems. ROM version updates are downloaded from disk for easy updating.

-Operate your isocratic system with a simplified parameter setup.Enter pump flow rate, detector wavelength, column oven temperature and auto injector batch schedule parameters, and begin your run.

Shimadzu SCSI & RAID Devices Driver Download For Windows

-The SCL-10AVP's advanced mode accesses full VP Series capability,including the autoinjector's automated advanced sample pre-treatment functionality. All operational parameters are controlled by the SCL-10AVP.

Specification

Display

Back-lit LCD display (320 × 240 dots)

Floppy Disk Drive

Double sided high density track, Disk: 2HD

Input/Output Terminals

External start input (MAN. INJ. in): 1

Error input (ALARM IN): 3

Output (EVENT1,2,3,4): 4

External power switch control (AC REMOTE): 1

Optical Link (OPT LINK): 1 (for Chromatopac)

RS-232C: 1 (for PC)

Remote Signal: 8 (for LC-10AVP/10A module

control)

Possible Component

Connection

Solvent delivery unit: max. 3

Autoinjector: 1

Column Oven: 1

Detectors: max. 2

Fraction Collector: 1

Sub-controller or valve interface: 1

2 or 6 position valve: 2 (via Sub-controller or

valve interface)

Solenoid valve unit: 1 (via Sub-controller or

solvent delivery unit)

He degassing unit: (via Sub-controller or

solvent delivery unit)

(Parameter setting files)

Analysis file

Time program

Fraction collector file

Time program

20 files (parameters, time programs)

Total 400 steps, 0.01~9999.9 min,

10 files (parameters, time programs)

Total 100 steps, 0.33~9999.9 min,

Autoinjector sequence file

or analysis sequence file

Autoinjector Sample

Pretreatment file

102 steps

20 files, 250 byte/file

Condition

Seller refurbished. Great working unit.

Shimadzu SCSI & RAID Devices Driver Download For Windows

Includes

  • Shimadzu SCL-10A vp configured with ver 5.4 software
  • power cord
Shimadzu scsi & raid devices driver download for windows 8.1

Warranty

Shimadzu Scsi & Raid Devices Driver Download For Windows 7

30 Day warranty. We pledge to offer the best service and warranty to all of our customers! We are extending a 30 Day warranty on this item. This is our way of saying thank you for allowing us to serve you.

Certification

Shimadzu Scsi & Raid Devices Driver Download For Windows 8.1

This is a genuine product from this manufacturer.

Shimadzu Scsi & Raid Devices Driver Download For Windows 10

You may also like...